gmail-final

enquiries@wbplumbing.co.uk

phonefinal

07594221501

location-final

48 Fieldway, Dagenham RM8 2BE, UK

INFORMATION QUESTIONS

FREQUENTLY ASKED QUESTIONS

On the average week, we can look to book your installation in within a week or two. We’ll work with you to select a time that is the most convenient and safest for you and your family during COVID-19, and we have applied additional cleaning steps as part of our installation process.

Depending on your requirements, the install time can vary between 1-2 days. To ensure we have enough time to complete your installation, we will review the job beforehand and book in the amount of time we think we’ll need to be at your property. Your price quoted would not change, unless there was additional work was requested after the online quote was completed.

Most installations which require a like-for like swap (An old combi boiler swapped for a new combi boiler) would be 1 day. 

As we’ve been working with certain boiler brands for a long time, and have good relationships with local merchants, we are able to purchase our boilers and parts at a reduced rate, passing this saving onto our customers.

We can either get the boiler delivered to your home on the day of the installation, or have it delivered to our address and bring it with us on the day. Your engineer will discuss this with you when confirming your boiler installation date/time.

We’re fully trained and accredited to work with Gas only.

Because we have extensive accreditations and training with many of the biggest household boiler names, we’re able to offer our customers a larger warranty period than a standard boiler installer on a variety of boiler models.

  1. Vaillant Boiler Advanced Installers
  2. Glowworm Club Energy Installers
Fault Code Possible Cause
F.00 / F.0 Flow temperature sensor interruption
F.01 / F.1 Return temperature sensor interruption
F.10 Flow NTC short circuit
F.11 Return NTC short circuit
F.20 Safety switch-off temperature limiter
F.22 Safety switch-off low water pressure
F.23 Safety switch-off temperature difference too great
F.24 Safety switch-off temperature is rising to fast
F.25 Safety switch-off flue gas temperature too high
F.26 Error with gas valve – possible no function
F.27 Safety switch-off flame simulation
F.28 Failure during start-up – ignition unsuccessful to start
F.29 Failure during operation – re-ignition unsuccessful
F.32 Fan error
F.49 eBUS error – possible short circuit
F.61 Error with gas valve regulation
F.62 Error with gas valve – switch-off delay
F.63 EEPROM error
F.64 Electronics / NTC error
F.65 Electronic temperature error could be overheating due to external influences
F.67 Electronics flame signal error
F.68 Unstable flame signal error air in gas
F.70 Invalid device-specific number (DSN)
F.71 Flow NTC error – flow temperature sensor signal constant value
F.72 Flow return NTC error – temperature difference too great
F.73 Water pressure sensor signal in the wrong range, it is too low
F.74 Water pressure sensor signal outside the correct range, the sensor signal is too high
F.75 Error with pressure – no pressure change detection when starting the pump
F.76 Overheating protection on – primary heat exchanger has responded
F.77 Flue non-return flap condensate pump error
F.78 Interruption to DHW outlet sensor at the external controller
F.83 Flow and or return temperature sensor error
F.84 Error with flow/return temperature sensor temperature changing error